10/03/2025 15:59:07:903; ; [OPCSCH]; Send call:setCicleJobData_CMD node ID:nsu=www.sigmatek-automation.com/euromap77/ ;ns=7;i=5016 call ID:nsu=www.sigmatek-automation.com/euromap77/ ;ns=7;i=7006; 10/03/2025 15:59:07:903; ; [OPCSCH]; Add input argument[1] with name:jobName|value:test_100325|type:System.String; 10/03/2025 15:59:07:904; ; [OPCSCH]; Add input argument[2] with name:jobDesc|value:test|type:System.String; 10/03/2025 15:59:07:904; ; [OPCSCH]; Add input argument[3] with name:custName|value:a|type:System.String; 10/03/2025 15:59:07:904; ; [OPCSCH]; Add input argument[4] with name:prodDataset|value:a|type:System.String; 10/03/2025 15:59:07:904; ; [OPCSCH]; Add input argument[5] with name:prodDatasetDesc|value:a|type:System.String; 10/03/2025 15:59:07:904; ; [OPCSCH]; Add input argument[6] with name:mat|value:{}|type:System.String; 10/03/2025 15:59:07:904; ; [OPCSCH]; Add input argument[7] with name:prodName|value:{}|type:System.String; 10/03/2025 15:59:07:904; ; [OPCSCH]; Add input argument[8] with name:prodDesc|value:{}|type:System.String; 10/03/2025 15:59:07:905; ; [OPCSCH]; Add input argument[9] with name:contJobEnd|value:False|type:System.Boolean; 10/03/2025 15:59:07:905; ; [OPCSCH]; Add input argument[10] with name:NomPart|value:10|type:System.UInt64; 10/03/2025 15:59:07:905; ; [OPCSCH]; Add input argument[11] with name:boxPart|value:1000|type:System.UInt64; 10/03/2025 15:59:07:905; ; [OPCSCH]; Add input argument[12] with name:expCicle|value:1200|type:System.Int16; 10/03/2025 15:59:07:905; ; [OPCSCH]; Add input argument[13] with name:mod_id|value:test|type:System.String; 10/03/2025 15:59:07:905; ; [OPCSCH]; Add input argument[14] with name:numCav|value:10|type:System.UInt32; 10/03/2025 15:59:07:905; ; [OPCSCH]; Send call:setCicleJobData_CMD with input arguments; 10/03/2025 15:59:07:916; ; [OPCSCH]; Send call:setCicleJobData_CMD error! => Exception: OpcLabs.EasyOpc.UA.OperationModel.UAException: An OPC-UA operation failure with error ID 'Opc.UA.ServiceResult=0x80AB0000' occurred, originating from 'OpcLabs.EasyOpcUA' and with depth of 1. The inner OPC-UA service exception with service result 'BadInvalidArgument' contains details about the problem. ---> OpcLabs.EasyOpc.UA.UACallServiceException: OPC UA service result - {BadInvalidArgument}. One or more arguments are invalid. + The method descriptor used was: NodeId="nsu=www.sigmatek-automation.com/euromap77/ ;ns=7;i=7006". + The node descriptor used was: NodeId="nsu=www.sigmatek-automation.com/euromap77/ ;ns=7;i=5016". + The client method called (or event/callback invoked) was 'CallMultipleMethods[1]'. --- Fine della traccia dello stack dell'eccezione interna --- in OpcLabs.EasyOpc.UA.IEasyUAClientExtension.CallMethod(IEasyUAClient client, UACallArguments callArguments) in OpcLabs.EasyOpc.UA.IEasyUAClientExtension.CallMethod(IEasyUAClient client, UAEndpointDescriptor endpointDescriptor, UANodeDescriptor objectNodeDescriptor, UANodeDescriptor methodNodeDescriptor, Object[] inputArguments, Type[] inputTypes) in OpcLabs.EasyOpc.UA.IEasyUAClientExtension.CallMethod(IEasyUAClient client, UAEndpointDescriptor endpointDescriptor, UANodeDescriptor objectNodeDescriptor, UANodeDescriptor methodNodeDescriptor, Object[] inputArguments) in Qualitas.DeviceApp.DataAccess.OPCserverCH.writeVariable(RunVariableVM rVarTMP, Object data)(An OPC-UA operation failure with error ID 'Opc.UA.ServiceResult=0x80AB0000' occurred, originating from 'OpcLabs.EasyOpcUA' and with depth of 1. The inner OPC-UA service exception with service result 'BadInvalidArgument' contains details about the problem.) Trace: in OpcLabs.EasyOpc.UA.IEasyUAClientExtension.CallMethod(IEasyUAClient client, UACallArguments callArguments) in OpcLabs.EasyOpc.UA.IEasyUAClientExtension.CallMethod(IEasyUAClient client, UAEndpointDescriptor endpointDescriptor, UANodeDescriptor objectNodeDescriptor, UANodeDescriptor methodNodeDescriptor, Object[] inputArguments, Type[] inputTypes) in OpcLabs.EasyOpc.UA.IEasyUAClientExtension.CallMethod(IEasyUAClient client, UAEndpointDescriptor endpointDescriptor, UANodeDescriptor objectNodeDescriptor, UANodeDescriptor methodNodeDescriptor, Object[] inputArguments) in Qualitas.DeviceApp.DataAccess.OPCserverCH.writeVariable(RunVariableVM rVarTMP, Object data);