OPC Studio User's Guide and Reference
HasConfigurationFileNode Method (IEasyUAPublishSubscribeClientExtension)



OpcLabs.EasyOpcUA Assembly > OpcLabs.EasyOpc.UA.PubSub.InformationModel.Extensions Namespace > IEasyUAPublishSubscribeClientExtension Class : HasConfigurationFileNode Method
A client for OPC UA PubSub information model.

This is typically the OpcLabs.EasyOpc.UA.PubSub.InformationModel.EasyUAPublishSubscribeClient object.

The value of this parameter cannot be null (Nothing in Visual Basic).

The endpoint descriptor of the OPC UA server containing the PubSub information model.

Because the OpcLabs.EasyOpc.UA.UAEndpointDescriptor has implicit conversions from System.String and System.Uri, in languages that support implicit conversion operators (such as C# or VB.NET), you can simply use a string (representing the endpoint URL, or a so-called OPC UA endpoint descriptor string), or a System.Uri object, in place of this parameter, and the corresponding endpoint descriptor will be constructed automatically. When the implicit conversion operators are not supported (such as with Python.NET), you can use the OpcLabs.EasyOpc.UA.UAEndpointDescriptor.FromString or OpcLabs.EasyOpc.UA.UAEndpointDescriptor.FromUri static method instead.

Also, because the OpcLabs.EasyOpc.UA.Discovery.UAApplicationElement and OpcLabs.EasyOpc.UA.Discovery.UADiscoveryElement have an implicit conversion to OpcLabs.EasyOpc.UA.UAEndpointDescriptor, in languages that support implicit conversion operators (such as C# or VB.NET), you can simply use a OpcLabs.EasyOpc.UA.Discovery.UAApplicationElement or OpcLabs.EasyOpc.UA.Discovery.UADiscoveryElement (results from OPC UA discovery) in place of this parameter, and the corresponding endpoint descriptor will be constructed automatically. When the implicit conversion operators are not supported (such as with Python.NET), you can convert a (non-null) OpcLabs.EasyOpc.UA.Discovery.UAApplicationElement or OpcLabs.EasyOpc.UA.Discovery.UADiscoveryElement to OpcLabs.EasyOpc.UA.UAEndpointDescriptor using the OpcLabs.EasyOpc.UA.Discovery.UAApplicationElement.ToUAEndpointDescriptor or OpcLabs.EasyOpc.UA.Discovery.UADiscoveryElement.ToUAEndpointDescriptor method instead.

If you are using OPC Wizard (for server development), an implicit conversion from OpcLabs.EasyOpc.UA.EasyUAServerCore can be used in the same way to simply pass the server object in place of this parameter, which will use its OpcLabs.EasyOpc.UA.EasyUAServerCore.EffectiveServerDescriptor property for the connection.

The value of this parameter cannot be null (Nothing in Visual Basic).

Determines whether there is a node representing the PubSub configuration as an OPC UA file object.
Syntax
'Declaration
 
<ExtensionAttribute()>
Public Shared Function HasConfigurationFileNode( _
   ByVal publishSubscribeClient As IEasyUAPublishSubscribeClient, _
   ByVal endpointDescriptor As UAEndpointDescriptor _
) As Boolean
'Usage
 
Dim publishSubscribeClient As IEasyUAPublishSubscribeClient
Dim endpointDescriptor As UAEndpointDescriptor
Dim value As Boolean
 
value = IEasyUAPublishSubscribeClientExtension.HasConfigurationFileNode(publishSubscribeClient, endpointDescriptor)

Parameters

publishSubscribeClient
A client for OPC UA PubSub information model.

This is typically the OpcLabs.EasyOpc.UA.PubSub.InformationModel.EasyUAPublishSubscribeClient object.

The value of this parameter cannot be null (Nothing in Visual Basic).

endpointDescriptor
The endpoint descriptor of the OPC UA server containing the PubSub information model.

Because the OpcLabs.EasyOpc.UA.UAEndpointDescriptor has implicit conversions from System.String and System.Uri, in languages that support implicit conversion operators (such as C# or VB.NET), you can simply use a string (representing the endpoint URL, or a so-called OPC UA endpoint descriptor string), or a System.Uri object, in place of this parameter, and the corresponding endpoint descriptor will be constructed automatically. When the implicit conversion operators are not supported (such as with Python.NET), you can use the OpcLabs.EasyOpc.UA.UAEndpointDescriptor.FromString or OpcLabs.EasyOpc.UA.UAEndpointDescriptor.FromUri static method instead.

Also, because the OpcLabs.EasyOpc.UA.Discovery.UAApplicationElement and OpcLabs.EasyOpc.UA.Discovery.UADiscoveryElement have an implicit conversion to OpcLabs.EasyOpc.UA.UAEndpointDescriptor, in languages that support implicit conversion operators (such as C# or VB.NET), you can simply use a OpcLabs.EasyOpc.UA.Discovery.UAApplicationElement or OpcLabs.EasyOpc.UA.Discovery.UADiscoveryElement (results from OPC UA discovery) in place of this parameter, and the corresponding endpoint descriptor will be constructed automatically. When the implicit conversion operators are not supported (such as with Python.NET), you can convert a (non-null) OpcLabs.EasyOpc.UA.Discovery.UAApplicationElement or OpcLabs.EasyOpc.UA.Discovery.UADiscoveryElement to OpcLabs.EasyOpc.UA.UAEndpointDescriptor using the OpcLabs.EasyOpc.UA.Discovery.UAApplicationElement.ToUAEndpointDescriptor or OpcLabs.EasyOpc.UA.Discovery.UADiscoveryElement.ToUAEndpointDescriptor method instead.

If you are using OPC Wizard (for server development), an implicit conversion from OpcLabs.EasyOpc.UA.EasyUAServerCore can be used in the same way to simply pass the server object in place of this parameter, which will use its OpcLabs.EasyOpc.UA.EasyUAServerCore.EffectiveServerDescriptor property for the connection.

The value of this parameter cannot be null (Nothing in Visual Basic).

Return Value

Returns true when the target OPC UA server contains a node with a PubSub configuration file object; returns false otherwise.
Exceptions
ExceptionDescription

A null reference (Nothing in Visual Basic) is passed to a method that does not accept it as a valid argument.

This is a usage error, i.e. it will never occur (the exception will not be thrown) in a correctly written program. Your code should not catch this exception.

The OPC UA operation has failed. This operation exception in uniformly used to allow common handling of various kinds of errors. The System.Exception.InnerException always contains information about the actual error cause.

This is an operation error that depends on factors external to your program, and thus cannot be always avoided. Your code must handle it appropriately.

Remarks

This method detects a PubSubConfiguration file node defined in OPC UA 1.05, or a vendor specific ConfigurationFile file node, present in servers implemented with Unified Automation (C++) toolkit.

Loading the configuration from a file node is typically faster than accessing it through individual nodes in the information model, but it only provides a one-time snapshot of the configuration.

This is an extension method (info: C#, VB.NET). In languages that have support for extensions methods (such as C# and VB.NET), you can use the extension method as if it were a regular method on the object that is its first parameter. In other languages (such as with Python.NET), you will call the extension as a static method, and pass it the object on which it acts as its first parameter.

Requirements

Target Platforms: .NET Framework: Windows 10 (selected versions), Windows 11 (selected versions), Windows Server 2016, Windows Server 2022; .NET: Linux, macOS, Microsoft Windows

See Also