OPC Studio User's Guide and Reference
SlowestAutomaticUpdateRate Property (DAAutoSubscribingParameters)



View with Navigation Tools
OpcLabs.EasyOpcClassicCore Assembly > OpcLabs.EasyOpc.DataAccess.Optimization Namespace > DAAutoSubscribingParameters Class : SlowestAutomaticUpdateRate Property
Slowest automatic update rate. Number of milliseconds. When the system automatically modifies the update rate of an OPC item, it never chooses a rate that is slower (has higher value) than the value of this property.
Syntax
'Declaration
 
<DataMemberAttribute()>
<ValueRangeAttribute(1, 2147483647)>
Public Property SlowestAutomaticUpdateRate As Integer
 
'Usage
 
Dim instance As DAAutoSubscribingParameters
Dim value As Integer
 
instance.SlowestAutomaticUpdateRate = value
 
value = instance.SlowestAutomaticUpdateRate

Property Value

Valid values of this property are in the range from 1 to 2147483647 (Int32.MaxValue).

The default value of this property is 1800000.

Remarks

The value must be greater than zero.

Requirements

Target Platforms: .NET Framework: Windows 10 (selected versions), Windows 11 (selected versions), Windows Server 2016, Windows Server 2022; .NET: Linux, macOS, Microsoft Windows